列头柜32回路600×600配置熔断器
(ID:2561956)截图
AI截图渲染
✨AI图片渲染
| # | 文件名称 | 文件大小 |
|---|---|---|
| 1 | 列头柜32回路600×600配置熔断器.SLDASM | 11.51M |
| 2 | C型梁.SLDPRT | 241.56K |
| 3 | 传感器安装板.SLDPRT | 183.34K |
| 4 | 出线霍尔传感器组合.SLDASM | 128.01K |
| 5 | 正负极隔板.SLDPRT | 108.98K |
| 6 | 浪涌保护器组合.SLDASM | 292.20K |
| 7 | 浪涌安装梁.SLDPRT | 265.23K |
| 8 | 熔断器RT00组合.SLDASM | 302.59K |
| 9 | 熔断器RT16-3-500.SLDASM | 269.33K |
| 10 | 熔断器RT18-32组合.SLDPRT | 6.90M |
| 11 | 熔断器安装板.SLDPRT | 159.49K |
| 12 | 电源模块安装板.SLDPRT | 116.79K |
| 13 | 电源模块组合.SLDASM | 113.85K |
| 14 | 绝缘子安装板.SLDPRT | 74.86K |
| 15 | 绝缘子组合.SLDASM | 258.80K |
| 16 | 绝缘子组合2.SLDASM | 254.15K |
| 17 | PE排.SLDPRT | 123.49K |
| 18 | 厦门分支排1.SLDPRT | 102.65K |
| 19 | 厦门分支排2.SLDPRT | 79.67K |
| 20 | 厦门垂直排1.SLDPRT | 64.52K |
| 21 | 厦门垂直排2.SLDPRT | 64.57K |
| 22 | 厦门延伸排.SLDPRT | 94.89K |
| 23 | 厦门延伸排2.SLDPRT | 95.56K |
| 24 | 正极排.SLDPRT | 135.27K |
| 25 | 正极连接排.SLDPRT | 106.38K |
| 26 | 负极排.SLDPRT | 98.09K |
| 27 | 负极连接排1.SLDPRT | 76.22K |
| 28 | 镜向负极排.SLDPRT | 34.36K |
| 29 | LOGO.SLDPRT | 10B |
| 30 | M12.SLDPRT | 380.97K |
| 31 | U型中立柱2200.SLDPRT | 488.37K |
| 32 | 上下挡板600.SLDPRT | 383.82K |
| 33 | 上眉头板600.SLDPRT | 808.54K |
| 34 | 下眉头板600.SLDPRT | 1.24M |
| 35 | 侧板600×2200.SLDPRT | 145.72K |
| 36 | 前后侧横梁600.SLDPRT | 212.43K |
| 37 | 前门600×2200.SLDPRT | 611.51K |
| 38 | 后门600×2200.SLDPRT | 489.30K |
| 39 | 平顶盖600×600.SLDPRT | 132.03K |
| 40 | 底板600×600.SLDPRT | 187.19K |
| 41 | 扎线杆600.SLDPRT | 68.50K |
| 42 | 横向向大横梁600.SLDPRT | 352.19K |
| 43 | 毛刷.SLDPRT | 773.24K |
| 44 | 竖向立柱2200.SLDPRT | 677.00K |
| 45 | 纵向立柱600.SLDPRT | 288.51K |
| 46 | 骨架600×600×2200.SLDASM | 7.18M |
| 47 | 内铰链HANL100001R1.SLDASM | 114.00K |
| 48 | 固定页.SLDPRT | 171.84K |
| 49 | 活动页.SLDPRT | 129.53K |
| 50 | 铰链轴.SLDPRT | 41.89K |
| 51 | 镜向MS818-1S.SLDPRT | 7.86M |
| 52 | 22指示灯红.SLDPRT | 134.58K |
| 53 | C45-DZ47导轨.SLDPRT | 89.80K |
| 54 | DZ47-60.SLDPRT | 511.19K |
| 55 | 浪涌保护器NU6-I-40-440_7822f_27.SLDPRT | 264.49K |
| 56 | 熔断器RT00-16.SLDPRT | 987.71K |
| 57 | 熔断器RT16-3-500.SLDPRT | 811.20K |
| 58 | 红色圆形绝缘子.SLDPRT | 73.29K |
| 59 | 触摸屏.SLDPRT | 1.09M |
| 60 | 霍尔出线传感器PMC-DCT-50A.SLDPRT | 148.95K |
| 61 | 霍尔智能监测PMC-412.SLDPRT | 128.99K |
| 62 | 霍尔电源模块URA4812LD-20WR3.SLDPRT | 129.94K |
| 63 | 黄色圆形绝缘子.SLDPRT | 155.31K |
| 64 | 列头柜铜排规格.jpg | 47.24K |
| 65 | 线缆规格要求.jpg | 149.91K |
| 66 | 线鼻DT-16.dwg | 37.93K |
| 67 | 线鼻DT-185.dwg | 44.77K |
| 68 | 线鼻DT-35.dwg | 34.89K |
| 69 | 线鼻DT-50.dwg | 36.90K |
| 70 | 铜鼻子规格铜鼻子型号大全带图片.doc | 443.50K |
此图纸下载需要200金币
立即下载
模型信息
图纸ID:2561956
图纸格式:sldasm,sldprt,dwg
文件大小:49.33M
所需金币:200
上传时间:2025-08-24 13:34:11
是否可编辑:可修改,包括参数
软件版本:SOLIDWORKS 2019
标签
电信行业
数据机房
成套机柜
强弱电
配电功能
图纸简介
列头柜是数据中心机房中用于电力分配与网络布线管理的核心设备,主要承担配电控制、系统监控和能效优化三大功能。核心功能解析电力分配与管理,集中接收上级配电柜或UPS电源。避免因电压波动导致的设备损坏,弱电列头柜集中管理光纤、网线等通信,系统实时监测电压、电流、功率等参数,并监控与保护。柜体尺寸600宽600深2200高,配置32回路的熔断器RT00-16。